Mortar Analysis – Limitations

Mortar analysis can be done various ways with several different approaches to identify the original mortar ingredients of a formulation. However, there are limitations and replacement mortar specifications should not be based solely on laboratory analysis. Analysis requires interpretation, and there are important factors which affect the condition and performance of the mortar that cannot be established through laboratory analysis. These may include: the original water content, rate of curing, weather conditions during original construction, the method of mixing and placing the mortar, and the cleanliness and condition of the sand (Pres. Brief 2 pg. 2).

Mortar can be evaluated by simple wet-chemistry of using hydrochloric acid and water to dissolve out the binder components (calcium carbonate) leaving only the sand particles behind. The ratio of binder to sand can be determined by drying the sample first then weighing it before and after the wet-chemistry process. The problem occurs when calcium carbonate is part of the sand component which would give you a false reading of the ratio. There is also x-ray diffraction, and petrographic analysis by microscope, as well as thin-section technology, where small samples of mortar are cut into very thin sections and dies are injected into the sample showing the different components of the mortar. In addition, ASTM C1324 is a test method to determine components of hardened mortar samples.

Sand particle shape from an analysis - Historic Scotland

The most useful information that can come from a laboratory analysis is the identification of the sand by gradation and color. This allows the color and the texture of the mortar to be matched with some accuracy because sand is the largest ingredient by volume.

A simple non-technical evaluation of the masonry units and the mortar can provide information concerning the relative strength and permeability of each-critical factors in selecting the repointing mortar – while visual analysis of the historic mortar compared to the new replacement repointing mortar can be made. It’s important to match the un-weathered portions of the historic mortar in case the building will be cleaned in the future, or cleaning should be taken into account before the sample is matched.

Advertisements

, , , , ,

  1. Leave a comment

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: